LURASIDONE, SERUM/PLASMA

Specimen Required
Draw blood in a plain red-top tube. Centrifuge, separate serum from cells and send 1.0 mL serum (0.3 mL minimum) refrigerated in a screw-capped plastic vial.

Alternate Specimen
Plasma: EDTA

Rejection Criteria
SST or PST

Methodology
High Performance Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)

Stability
Room temperature: 30 days; Refrigerated: 30 days; Frozen: 15 months

Reference Range
By report

Performed
Monday-Sunday

Turnaround Time8-14 days
Test CodeLURAS
CPT-4 Code (s)
80342 (80299)
LOINC Codes
Not available