Test Details

Mnemonic

PNE23

Ordering Code

3803100

CPT-4 Code(s)

86317 x 23

Specimen Information

Collect

Serum separator tube (SST)

Specimen Preparation

Centrifuge, separate and send 0.5 mL serum in a screw capped plastic vial.

Alternate Specimen

Serum: Red top

Minimum Volume

0.4 mL

Transport Temperature

Refrigerated

Rejection Criteria

Grossly hemolyzed or lipemic specimens

Stability

Room temperature: Unacceptable
Refrigerated: 21 days
Frozen: 21 days

Methodology

Microsphere Photometry
more

Reference Range

See report
more

Performing Laboratory

Mayo Clinic Laboratories
more

New York DOH Approval Status

Yes
more