Updated Test

Effective Date

11/14/2022

Notes

ARUP 005863 – Replace (0051690): changes to specimen name, requirements, specimen type, stability, rejection criteria, methodology, reference range, Performed days.

Specimen Information

Update to test name.

Transforming Growth Factor beta1, Plasma -> Transforming Growth Factor beta1, SerumĀ 

Collect

Previous:Updated To:
Lavender

Specimen Preparation

Previous:Updated To:
Centrifuge anticoagulated whole blood within 2 hours of collection at 1500 g for 10 minutes. Collect plasma and transfer to fresh tube. Immediately centrifuge plasma at 3000 g for 10 minutes. Collect plasma from upper 2/3 of tube without disturbing lower 1/3 of tube and transfer to fresh tube for storage or transport. Separate plasma from cells ASAP or within 2 hours of collection. Send 1.0 mL plasma in a screw capped plastic vial. CRITICAL FROZEN
  
Separate specimens must be submitted when multiple tests are ordered.

Rejection Criteria

Previous:Updated To:
Contaminated, severely hemolyzed, heat-inactivated or grossly lipemic specimens

Stability

Previous:Updated To:
After separation from cells:
Room temperature: 30 minutes
Refrigerated: Unacceptable
Frozen: 60 days

Methodology

Previous:Updated To:
Quantitative Enzyme-Linked Immunosorbent Assay

Reference Range

Previous:Updated To:
1654 - 19951 pg/mL

New York DOH Approval Status

Previous:Updated To:
Pending

Days Performed

Previous:Updated To:
Monday