Test Details
Mnemonic
BNPAR
Ordering Code
3619320
CPT-4 Code(s)
83880
Specimen Information
Collect
Lavender EDTA
Specimen Preparation
Centrifuge, separate plasma from cells within 2 hours and send 2.0 mL plasma frozen in a screw capped plastic vial.
Minimum Volume
0.5 mL
Transport Temperature
Frozen
Rejection Criteria
Frozen whole blood, specimens frozen in separator tubes, hemolyzed specimens
Stability
Room temperature: 4 hours
Refrigerated: 4 hours
Frozen: 4 months
Refrigerated: 4 hours
Frozen: 4 months
Methodology
Quantitative Chemiluminescent Immunoassay
Reference Range
A cutoff of 100 pg/mL has been demonstrated to
provide the maximal combination of sensitivity,
specificity and negative predictive value for
contributing to the diagnosis of congestive
heart failure (CHF). A BNP value greater than
100 pg/mL is consistent with a diagnosis of CHF
in the appropriate clinical setting. False-positive
results are more common in females greater than
75 years of age. Blood concentrations of natriuretic
peptides may also be elevated in patients with
myocardial infarction and in patients who are
candidates for or are undergoing renal dialysis.
provide the maximal combination of sensitivity,
specificity and negative predictive value for
contributing to the diagnosis of congestive
heart failure (CHF). A BNP value greater than
100 pg/mL is consistent with a diagnosis of CHF
in the appropriate clinical setting. False-positive
results are more common in females greater than
75 years of age. Blood concentrations of natriuretic
peptides may also be elevated in patients with
myocardial infarction and in patients who are
candidates for or are undergoing renal dialysis.
Performing Laboratory
ARUP
New York DOH Approval Status
Yes