Test Details

Mnemonic

LURAS

Ordering Code

3301800

CPT-4 Code(s)

80342 (G0480)

Specimen Information

Collect

Red top

Specimen Preparation

Centrifuge, separate serum from cells and send 1.0 mL serum in a screw capped plastic vial.

Alternate Specimen

Plasma: EDTA

Minimum Volume

0.3 mL

Transport Temperature

Refrigerated

Rejection Criteria

Serum separator tube (SST) or Plasma separator tube (PST)

Stability

Room temperature: 30 days
Refrigerated: 30 days
Frozen: 15 months

Methodology

High Performance Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)
more

Reference Range

See report
more

Performing Laboratory

NMS Labs
more

New York DOH Approval Status

Yes
more