Test Details

Mnemonic

GCPCR

Ordering Code

3000482

CPT-4 Code(s)

87591

Specimen Information

Collect

Variable specimen types

Specimen Preparation

Endocervical swab, first catch urine, rectal swab, oropharyngeal swab specimens.
Swab specimens must be collected using the Alinity m Multi-Collect Collection Kit. Urine specimens must be first catch and the swab can be discarded. Patients should not have urinated more than 1 hr prior to collection.

Alternate Specimen

Urine may be collected in an screw capped plastic container but must be tranferred to the Alinity m Multi-Collect Collection Kit with 24 hours.

Rejection Criteria

Specimens submitted with the white cleaning swab or with two swabs. Swabs in any media (e.g., M4, UTM, or Aptima media) other than the Alinity m Multi-Collect Collection Kit. Urine specimens where the liquid level in the urine transport tube does not fall within the clear fill window of the transport tube label (do not overfill). Urine specimens in sterile containers that have exceeded the 24 hour stability. Specimens collected in liquid cytology containers or media will not be tested.
Male urethral swab

Stability

Swab/urine in Multi-Collect
Room temperature: 14 days
Refrigerated: 14 days
Frozen: 60 days
Urine
Room temperature: Unacceptable
Refrigerated: 24 hours
Frozen: 4 days

Methodology

Polymerase Chain Reaction (PCR)
more

Reference Range

Not detected
more

Performing Laboratory

Warde Medical Laboratory
more

New York DOH Approval Status

Yes
more